Nortel 5510: Unterschied zwischen den Versionen
Zur Navigation springen
Zur Suche springen
Thomas (Diskussion | Beiträge) |
Thomas (Diskussion | Beiträge) |
||
Zeile 15: | Zeile 15: | ||
Press 'r' to Receive cascade test packets | Press 'r' to Receive cascade test packets | ||
Press 's' to Send cascade test packets.. | Press 's' to Send cascade test packets.. | ||
− | <pre> | + | </pre> |
#Press ' i ' to Initialize config/log flash. | #Press ' i ' to Initialize config/log flash. | ||
<pre> | <pre> |
Version vom 13. März 2017, 11:37 Uhr
Reset
- Follow these steps:
- Connect to the console port of the switch (9600,8,N,1)
- Reboot (power-cycle) the switch.
- When the first line of the diagnostics tests is displayed, press CTRL-C. The system then displays a menu.
>> Break Recognized - Wait.. Press 'a' to run Agent code Press 'c' to run Cascade external loopback test Press 'd' to Download agent code Press 'e' to display Errors Press 'i' to Initialize config/log flash Press 'p' to run POST tests Press 'r' to Receive cascade test packets Press 's' to Send cascade test packets..
- Press ' i ' to Initialize config/log flash.
Erase Config/Log Flash? y/N [ N ]: y Erasing - Done Press ' a ' to run Agent code. The switch will reboot.
- show system verbose